Battery Extra Load Unit – BXL-V

Overview

Home
DvPower
BATTERY TEST EQUIPMENT
Battery Extra Load Units – BXL Series
Battery Extra Load Unit – BXL-V

The Battery Extra Load Unit BXL-V is used as an additional load with the BLU360V device if a required discharge current or power exceeds the capacity of a single BLU360V device.

The BXL-V unit solution is based on the state-of-the-art technology using the most advanced power electronics solutions, with 8 fans integrated into the device itself. The BXL-V is powerful, providing high discharge currents of up to 190 A DC and applicable for battery systems with up to 480 V DC voltage range. A combination of the BLU and BXL devices enables performing the capacity test in an accurate, user-friendly way in accordance with the battery testing standards (IEEE 450-2010 / 1188-2005 / 1106-2015, IEC 60896-11/22 and other relevant standards).

Tekon Enerji

    • Used in a combination with BLU360V device to increase load capacity
    • Lightweight – 16 kg (35 lb.)
    • Powerful – discharge power up to 35 kW
    • Voltage measurement range: 0 – 480 V DC
    • Discharge current – up to 190 A DC
    • Measurement resolution – current 1 A, voltage 1 V
    • Discharge process controlled by BLU360V device
    • Connects to battery terminals and parallel to BLU360V

  • Included accessories
    • Mains power cable
    • Ground (PE) cable
    • Transport case
    Recommended accessories
    • Current cables 2 x 3 m 35 mm2
       (9.84 ft, 2 AWG) with alligator
      clamps (A4) isolated
    • Cable bag
    Optional accessories
    • Current cables 2 x 5 m 35 mm2 with alligator
      clamps (A4) isolated
    • Current cables 2 x 10 m 35 mm2 with alligator
      clamps (A4) isolated
    • Current cables 2 x 15 m 50 mm2 with alligator
      clamps (A4) isolated
    • Current cables 2 x 20 m 50 mm2 with alligator
      clamps (A4) isolated
    • Extension cables 2 x 5 m 35 mm2
    • Extension cables 2 x 10 m 35 mm2
    • Extension cables 2 x 10 m 50 mm2
    • Cable set 2 x 2 m 1 mm2 for parallel operation
    • Cable set 2 x 5 m 1 mm2 for parallel operation

  • Mains Power Supply

    • Connection: according to IEC/EN60320-1; C320
    • Voltage: 90 V – 264 V AC, 50 / 60 Hz, single-phase
    • Input power: 200 VA
    • Fuse: 2 A / 250 V, type F


    Dimensions and Weight

    • Dimensions (D x W x H) without handle: 730 mm x 221 mm x 355 mm
      28.7 in   x   8.7 in   x   14 in
    • Weight: 16 kg / 35 lb.


    Maximum discharge current & power

       Battery
       voltage
          6 V       12 V       24 V       48 V       60 V       110 V       120 V       220 V       240 V       480 V
    Min-Max    voltage (V) 5,25 7,05 10,5 14,1 21,0 28,2 42,0 56,4 52,5 70,5 96,3 129,3 105,0 141,0 192,5 258,5 210,0 282,0 300 480
    BXL-V max. current (A) 11 15 26 35 55 75 115 155 141 190 96 130 107 145 85 115 93 125 34 55
    • Maximum power: 35 kW

    Measurement

    Internal voltage measurement

    • Range: 0 – 480 V DC
    • Resolution: 1 V
    • Typical accuracy: ± 0,5% of reading ± 1 V


    Internal current measurement

    • Range: 0 – 250 A DC
    • Resolution: 1 A
    • Typical accuracy: ± 0,5% of reading ± 1 A


    Display

    • LCD screen 16 characters by 2 lines,
    • LCD display with backlight, visible in bright sunlight


    Warranty

    • The transport case is considered as the standard accessory for this device. Ordering the device with it provides the 3-year manufacturer’s warranty. Avoiding to include it in a purchase order will provide 15 calendar month warranty.


    Environmental conditions

    • Operating temperature: -10 °C to +50 °C / 14 °F to +122 °F
    • Storage & Transportation temperature: -40 °C to +70 °C / -40 °F to +158 °F
    • Humidity: 90%, non-condensing
    • Pollution degree 2


    Safety

    • Low Voltage Directive 2014/35/EU (CE Conform)
    • Applicable standards, for a class I instrument, pollution degree 2,
      Installation category II : IEC EN 61010-1
    • CAN/CSA-C22.2 No. 61010-1


    Electromagnetic Compatibility

    • Directive 2014/30/EU (CE Conform)
    • Applicable standard EN 61326-1


    All specifications listed herein are valid at the ambient temperature of + 25 °C (77°F) and with the recommended accessories included.

    Specifications are subject to change without notice.

BATTERY TEST EQUIPMENT

Tekon Enerji

Battery Load Units

Battery Load Units

Battery Charger - BAC25A

Battery Charger - BAC25A

Battery Voltage Supervisor - BVS New

Battery Voltage Supervisor - BVS New

Battery Extra Load Units – BXL Series

Battery Extra Load Units – BXL Series

Battery Voltage Recorder

Battery Voltage Recorder

Tekon Enerji

YOU NEED A PARTNER WHO CAN BRING CLARITY TO THE COMPLEXITY.


Tekon Enerji