Home
DvPower
BATTERY TEST EQUIPMENT
Battery Load Units

Battery Load Units

BLU SERIES BLU-K SERIES
BLU100A BLU100K
BLU200A BLU200K
BLU340A BLU340K
BLU220T BLU220TK
BLU360V BLU360VK
BLU SERIES BROCHURE BLU-K SERIES BROCHURE
 

BLU & BLU-K Series

Batteries are crucial component to the overall reliability of a substation. Inability of a battery string to provide a sufficient voltage / power supply to protection circuits may lead to catastrophic consequences to the substation equipment resulting in a power outage.

The essential test for a condition assessment of a battery string is the capacity test. Listening to the demands of the test engineers from all around the world, we developed state-of-the-art battery testing solutions to meet customer’s wide ranging test procedures (standardized as well as customized).

The BLU & BLU-K series of battery load units are a lightweight, accurate, user-friendly capacity test tools applicable to battery strings with up to 480 V voltage level. By providing high discharge current / power, these units represent a universal solution that can be used for the discharge test on various battery strings. In case a required discharge current or power exceeds the capacity of available BLU / BLU-K devices, an External Load Unit BXLcan be used to increase discharging capacity.

BLU vs. BLU-K Series comparison sheet 

  BLU SERIES BLU-K SERIES
 Voltage measurement
 range
5 – 480 V DC
(depends on the model)
5 – 480 V DC
(depends on the model)
 Maximum discharge
 current
160 A DC up to 340 A DC
(depends on the model)
150 A DC up to 330 A V DC
(depends on the model)
 Maximum discharge
 power
14,2 kW up to 28,4 kW
(depends on the model)
14,2 kW up to 28,2 kW
(depends on the model)
 Weight 12,8 / 28 (kg / lbs) up to
20,6 / 45.4 (kg / lbs)
(depends on the model)
12,8 / 28 (kg / lbs) up to
20,6 / 45.4 (kg / lbs)
(depends on the model)
 Test modes* Single, CP Load current,
CP Battery current and
Parallel mode
Single, CP Load current and
CP Battery current
 Display 4,3 inch
color touch screen display
LCD screen
20 characters by 4 lines
 USB FLASH DRIVE yes no
 External (substation)
 alarm triggering
 feature
yes no
 External load
 triggering feature
yes yes
 Expandable for larger
 load banks
 (using current probe)
yes yes
 Test resume feature in
 case of interrupted
 power supply
yes yes
 Test control and
 monitoring via
 software
yes yes

YES-ES, NO-NO

* Single mode – One BLU / BLU-K unit is used for the discharge test (regular load is disconnected, additional load units are not used),

* CP Load / Battery mode – Used when regular load remains connected to a battery during the discharge, and / or any additional loads (such as BLU / BLU-K units and external BXL units) are used to increase discharge capacity. A current probe measures load current or total battery current, depending on the selected mode and the probe connection point.

* Parallel mode – Two or more BLU devices (up to ten), connected by network cables as a daisy chain, discharge a battery simultaneously (a current probe is not required).


 

Tekon Enerji
Tekon Enerji

BLU Series

-

BLU-K Series

-
Tekon Enerji

YOU NEED A PARTNER WHO CAN BRING CLARITY TO THE COMPLEXITY.


Tekon Enerji